www.BOPDepot.com
Call now: 281-440-5555 Fax. (713)583-8020 Quote@EZequipmentOutlet.com

      Blowout preventers (BOPs) are used to control blowout. The crew usually install several blowout preventer (BOP stack) on top of the well, with an annular blowout preventer

at the top and at least one pipe ram and one blind ram blowout preventer below. Also, some well control techniques require both the annular and the ram blowout preventer.







Type GK Style Annular BOP

u  Type GK Style Annular BOP has a tapered rubber sealing element

    That can seal different sizes and shapes of pipe string and drill tools and also close an empty hole

u   Bore: 7 1/16 ", 9", 11", 135/8 ", 163/4", 211/4"

u   Working Pressure: 2,000psi 10,000psi

u   Hydraulic Control Pressure: 1,500psi

u   Top Connection: Studded 71/16 " 211/4 "

u   Bottom connection: Flanged 71/16 " 211/4 "

u   Weight: 4250 lbs 16,890 lbs

u   Standard: API 16A

   


Type Annular BOP

u   Type OBP-2 simple structure, less maintenance

u   Low one-piece height to save installation space.

u   Large volume of spherical rubber sealing element, long

u   service life.                              

u   Wide sealing range, BOP can seal different sizes and shapes

    of pipe string, drill tools and wireline/cable not more than                                          

    BOP bore size in diameter.

u   Quick and reliable hydraulic drive.

u   Bore: 7 1/16 " ~ 135/8 "   

u   Working Pressure: 3,000psi ~ 5,000psi

u   Hydraulic Control Pressure: 1,500psi

u   Top Connection: Studded 71/16 " ~ 135/8 "

u   Bottom connection: Flanged 71/16 " ~ 135/8 "

u   Weight: 3,350 lbs ~ 14,873 lbs

u   Standard: API 16A